X-Ray Equipment

Highly stabilized 40 Khz Digital Constant Potential X-ray Equipment

COMET's unipolar and bipolar constant potential X-ray systems include 4.5 kW- 40Khz Power supplies. The typical application of each system is tailored towards specific target areas like low density applications, biological specimens (pathology), plastics and rubber compounds and aluminum (XRS-160) and light steel applications like casting inspection utilize the (XRS-225).

The high energy and the high dose rates of the 320kV (XRS-320) and the 450kV (XRS-450) bipolar systems can be used for a wide variety of applications ranging from light alloys and thin walled materials of low density to thick walled materials of high density as e.g. 115 mm iron.

The 40 kHz X-ray systems feature very high output stability, a precise energy setting and an extreme fast change over to any selected new value. Any fluctuation or deviation of set values are controlled and corrected within microseconds. These features make the system an excellent candidate not only for radiographic and radioscopic applications but also for scanning methods like tomography and even in the field of dosimetry. In addition these features reduce inspection times considerably, an important economical aspect.

The wide range of use calls for an universal easy to use control system realized in the MGC41. The set-up modes are menu driven. All indications, operating mode and fault diagnosis of internal or external errors are displayed in clear text with the comfort of being able to choose optional languages. Additional error indications are given by numerical codes.

All system components are protected against the influence of dust and water. H.V Generators and Power supplies meet the requirements of IP54.

The wide range of use calls for a universal, easy to use control system realized in the MGC41.

The set-up modes are menu driven. All signals, operating mode and fault diagnosis of internal or external errors are displayed in clear text which can be easily displayed in a number of optional languages. Additional error indications are given by numerical codes. Furthermore, 100 technique programs can be stored for future use, and when connected through the serial port interface, an infinite number of programs may be stored on the host computer.

All system components are protected from water damage. H.V Generators and Power supplies meet the requirements of IP54.


XRS-160kV utilized with 
										max 3.0kW x-ray tube

XRS-160kV utilized with max 3.0kW x-ray tube

XRS-225kV

XRS-225kV


XRS-320kV utilized with
										max 4.2kW x-ray tube

XRS-320kV utilized with max 4.2kW x-ray tube

XRS-450kV utilized with
										max 4.5kW x-ray tube

XRS-450kV utilized with max 4.5kW x-ray tube